AUTOMATIC REMOTE CAPABLE SAFETY PILOT SYSTEM
FEATURES:
NON-STANDING FLAME-SENSING PILOT •
MANUAL SWITCH ON/OFF •
• OPTIONAL REMOTE CONTROL •
• BATTERY OPERATION •
(Suitable for G4, G45, and PB series burners)
(Sizes 12"- 24" for natural; 12"- 36" for propane gas)
PRE-ASSEMBLED
READY FOR INSTALLATION
EPK-1(M)(P) Installed
OWNER’S
MANUAL
RHP
The Peterson Real-Fyre
®
gas log set is to be installed
only in a solid-fuel-burning fi replace with a working
ue constructed of noncombustible material. Solid
fuels shall not be burned in a fi replace where this
gas log set is installed. The installation, including
provisions for combustion, ventilation air, and required
minimum permanent vent opening, must conform with
the National Fuel Gas Code (ANSI Z223.1/NFPA 54)
and applicable local building codes. In Canada, the
installation must conform with the Natural Gas and
Propane Storage and Handling Installation Code
(CSA-B-149.1). A damper stop clamp is included
to maintain the minimum permanent vent opening
and to prevent full closure of the damper blade. The
chimney damper must be fi xed fully opened when
burning this log set. This log set is designed to
burn with yellow fl ames; thus, adequate ventilation
is absolutely necessary.
INSTALLER & CONSUMER
These instructions MUST be
retained with this appliance
MODEL EPK-1(M)(P)
®
Do not store or use gasoline or other
ammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
Open a window.
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in the building.
Immediately call the gas supplier from
a neighbor’s phone and follow the gas
supplier’s instructions.
If you cannot reach the gas supplier,
call the fi re department.
WARNING
If the information in this manual is not followed
exactly, a fi re or explosion may result, causing
property damage, personal injury, or loss of life.
Installation and service must be
performed by an NFI Certifi ed or other
qualifi ed professional installer, service
agency, or the gas supplier.
Seitenansicht 0
1 2 3 4 5 6 7 8 9 10

Inhaltsverzeichnis

Seite 1 - Robert H. Peterson Co

1L-A2-10208Rev 3 - 0801151103Important: Read these instructions carefully before starting installation of the burner control system.Robert H. Peterso

Seite 2 - TABLE OF CONTENTS

10PLEASE KEEP A COPY OF YOUR SALES SLIP FOR PROOF OF PURCHASEThis warranty applies to the original purchaser and to single family residential use only

Seite 3 - EPK-1(M)(P) PARTS LIST

2L-A2-10208Rev 3 - 0801151103CHECK TO BE SURE THAT THE PROPER FUEL GAS IS BEING USED WITH THIS PILOT KIT.The installation, including provisions for co

Seite 4 - INSTALLATION

3L-A2-10208Rev 3 - 08011511032812VelcrostripsON/OFFSwitchRear view of the pine cone assemblyshowing battery & ignition module packs.FOR WIRING DIA

Seite 5 - INSTALLATION (Cont.)

4L-A2-10208Rev 3 - 0801151103HOW TO INSTALL THE EPK-1(M)(P) SAFETY PILOT SYSTEMThis safety pilot system must be installed by a qualifi ed professional

Seite 6

5L-A2-10208Rev 3 - 0801151103INSTALLATION (Cont.)INSTALLING THE PILOT ASSEMBLY TO THE BURNERCaution: Do not kink or damage the pilot supply tube, spa

Seite 7

6L-A2-10208Rev 3 - 0801151103ISISWiring diagram for EPK-1(M)(P)Fig. 6-3Consult this wiring diagram to ensure correct connection of wires. TO CHECK TH

Seite 8 - LIGHTING INSTRUCTIONS

7L-A2-10208Rev 3 - 0801151103INSTALLING OR REPLACING BATTERIES FOR THE IGNITION MODULE PACK Two 1.5-volt (D-cell) alkaline batteries come supplied wit

Seite 9

8L-A2-10208Rev 3 - 0801151103TO LIGHT THE BURNER SYSTEM USING THE PINE CONE SWITCHUse the switch on the top of the decorative pine cone (marked I = IG

Seite 10 - ROBERT H. PETERSON CO

9L-A2-10208Rev 3 - 0801151103TROUBLESHOOTING THE EPK-1(M)(P) PROBLEM CAUSE SOLUTION1. Pilot will not light a. Obstruction in pilot gas supply or pil