R.H. Peterson G4 Bedienungshandbuch

Stöbern Sie online oder laden Sie Bedienungshandbuch nach Kamine R.H. Peterson G4 herunter. R.H. Peterson G4 Owner`s manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 18
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
1
No. L-A2-01309
REV 4 - 0907131103
Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS:
Open a window.
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in the building.
Immediately call the gas supplier from
a neighbor’s phone and follow the gas
supplier’s instructions.
If you cannot reach the gas supplier, call the
re department.
If the information in this manual is not followed
exactly, a fi re or explosion may result, causing
property damage, personal injury, or loss of life.
This burner system is to be installed only in a solid-fuel-
burning fi replace with a working fl ue and constructed
of noncombustible material. Solid fuels shall not be
burned in a fi replace where this gas log set is installed.
The installation, including provisions for combustion,
ventilation air, and required minimum permanent vent
opening, must conform with the National Fuel Gas
Code (
Z223.1) and applicable local building codes. A
damper stop clamp is included to maintain the minimum
permanent vent opening and to prevent full closure of
the damper blade. The chimney damper should be
fully opened when burning the log set. The log set is
designed to burn with yellow fl ames; thus, adequate
ventilation is absolutely necessary.
Owner’s
Manual
G4/GX4 SERIES BURNER
Installation and service must be performed
by an NFI Certifi ed or other qualifi ed
professional installer, service agency, or
the gas supplier.
Woodland Oak (WOG4-24) Shown
INSTALLER & CONSUMER
These instructions MUST be retained
with this appliance.
WARNING
We recommend that our gas
hearth products be installed
and serviced by professionals
who are certifi ed in the U.S.
by the National Fireplace
Institute
®
(NFI) as NFI Gas
Specialists.
Important: Read these instructions carefully before
starting installation of the gas log set.
ROBERT H. PETERSON CO. • 14724 East Proctor Avenue • City of Industry, CA 91746
Important: To comply with certifi cation, listings, and
building code acceptance, and for safe
operation and proper performance,
ONLY Peterson parts and accessories
may be used with this gas log set.
Seitenansicht 0
1 2 3 4 5 6 ... 17 18

Inhaltsverzeichnis

Seite 1 - G4/GX4 SERIES BURNER

1No. L-A2-01309REV 4 - 0907131103Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.WHA

Seite 2 - Some Available Log Styles:

10REV 4 - 0907131103No. L-A2-01309Fig. 10-13. Pour a small amount of the granules along the outside bottom edges and back of the burner pan. This pre

Seite 3 - PARTS LIST

11REV 4 - 0907131103No. L-A2-01309GAS LOG PLACEMENTThe beauty and design of the Real-Fyre® gas logs are the result of skilled craftsmanship, research,

Seite 4 - FIREPLACE REQUIREMENTS

12REV 4 - 0907131103No. L-A2-01309EMBER COALS PLACEMENTAttach the ember bed (part No. CHD-01) to the burner by slipping it onto the back edge (center

Seite 5 - INSTALLING THE BURNER SYSTEM

13REV 4 - 0907131103No. L-A2-01309Before operating the gas log set:1. Be sure the fi replace is free from fl ammable liquids or combustible materials.2

Seite 6 - Fig. 6-1

14REV 4 - 0907131103No. L-A2-01309MAINTENANCE Once installed and operating properly, the Real-Fyre® gas log set requires very little maintenance. You

Seite 7 - Fig. 7-2 - AV series

15REV 4 - 0907131103No. L-A2-01309TROUBLESHOOTING THE GAS LOG SETSYMPTOM CAUSE SOLUTION1.Excessive smoking and sooting Note: As with burning natural

Seite 8 - FRONT FLAME BOOSTER

16REV 4 - 0907131103No. L-A2-01309TROUBLESHOOTING THE GAS LOG SET (Cont.) SYMPTOM CAUSE SOLUTION3. Uneven flame distribution (Lower at one end of th

Seite 9 - Fig. 9-4 - APK-17(M)(P)

17OPTIONAL CONTROLS FOR YOUR REAL-FYRE® BURNER SYSTEMThis unit may come without a valve installed.It may be connected directly to and operated by your

Seite 10 - IMPORTANT

18PLEASE KEEP A COPY OF YOUR SALES SLIP FOR PROOF OF PURCHASEThis warranty applies to the original purchaser and to single family residential use only

Seite 11 - GAS LOG PLACEMENT

2REV 4 - 0907131103No. L-A2-01309TABLE OF CONTENTSIMPORTANT - Read This Manual Carefully Before Starting Installation of the Log Set FOR YOUR SAFETYDo

Seite 12 - CHARRED SERIES LOG PLACEMENT

3REV 4 - 0907131103No. L-A2-01309PARTS LISTBefore beginning installation, be sure the gas log set is complete by comparing its contents with this PART

Seite 13 - gas log set, turn the

4REV 4 - 0907131103No. L-A2-01309BEFORE YOU BEGIN - IMPORTANT INFORMATIONBefore you begin, review the below information and safeguards about the insta

Seite 14 - MAINTENANCE AND SERVICE

5REV 4 - 0907131103No. L-A2-01309INSTALLING THE DAMPER CLAMPFig. 5-1Damper clampINSTALLING THE BURNER SYSTEMA damper clamp (Item #8) is provided as a

Seite 15 - SYMPTOM CAUSE SOLUTION

6REV 4 - 0907131103No. L-A2-013093. Check to be sure the Real-Fyre® gas log set is designed for the type of gas that fuels the fi replace.4. Be sure

Seite 16 - REV 4 - 0907131103

7REV 4 - 0907131103No. L-A2-01309Check to see if the burner fuel injector or air mixer is installed on the side of the burner closest to the gas con

Seite 17

8REV 4 - 0907131103No. L-A2-01309INSTALLING THE BURNER SYSTEM (Cont.)Fig. 8-1 - SPK-20 system 13C. Installing the Real-Fyre® gas log set using a Pete

Seite 18 - WARRANTY

9REV 4 - 0907131103No. L-A2-01309INSTALLING THE BURNER SYSTEM (Cont.)Fig. 9-1- APK-10(M)(P)Fig. 9-2 - APK-11(M)(P)13D. Installing the Real-Fyre® gas