Seitenansicht 0
1
L-A2-256
Rev 6 - 1501210930
Important: Read these instructions carefully
before starting installation of the
burner control system.
Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, California 91746
INSTALLATION &
OWNER’S MANUAL
The Peterson Real-Fyre
®
burner system is to be
installed only in a solid-fuel-burning fi replace with a
working fl ue constructed of noncombustible material.
Solid fuels shall not be burned in a fi replace where the
unit is installed. The installation, including provisions
for combustion, ventilation air, and required minimum
permanent vent opening, must conform with the
National Fuel Gas Code (ANSI Z223.1/NFPA 54)
and applicable local building codes. In Canada, the
installation must conform with the Natural Gas and
Propane Storage and Handling Installation Code
(CSA-B-149.1). A damper stop clamp is included to
maintain the minimum permanent vent opening and to
prevent full closure of the damper blade. The chimney
damper must be fi xed fully opened when burning
the unit. The burner system is designed to burn
with yellow fl ames; thus, adequate ventilation is
absolutely necessary.
INSTALLER & CONSUMER
These instructions MUST be
retained with this appliance
APK-17 PILOT KITS
Do not store or use gasoline or other
ammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
Open a window.
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in the building.
Immediately call the gas supplier from
a neighbor’s phone and follow the gas
supplier’s instructions.
If you cannot reach the gas supplier,
call the fi re department.
WARNING
If the information in this manual is not followed
exactly, a fi re or explosion may result, causing
property damage, personal injury, or loss of life.
Installation and service must be
performed by an NFI Certifi ed or other
qualifi ed professional installer, service
agency, or the gas supplier.
AUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM
WITH VARIABLE FLAME-HEIGHT REMOTE
FOR NATURAL OR PROPANE GAS
FEATURES:
• CONTROL OPERATED ON/OFF •
VARIABLE FLAME-HEIGHT REMOTE •
VARIABLE FLAME HEIGHT CONTROL •
• STANDING PILOT •
SUITABLE FOR THE FOLLOWING BURNERS:
• PAN BURNERS (P-SERIES) •
• G4 SERIES BURNERS •
• G45 SERIES BURNERS •
Models:
APK-17(M)(P)
Seitenansicht 0
1 2 3 4 5 6 ... 13 14

Inhaltsverzeichnis

Seite 1 - WARNING

1L-A2-256Rev 6 - 1501210930Important: Read these instructions carefully before starting installation of the burner control system.Robert H. Peterson C

Seite 2 - TABLE OF CONTENTS

10LIGHTING INSTRUCTIONS - 17 SERIESFOR YOUR SAFETY READ BEFORE LIGHTINGWARNING: If you do not follow these instructions exactly, a fi re or explosion

Seite 3 - SPECIFICATIONS

11LIGHTING INSTRUCTIONS - 17 SERIES (cont.)2. Locate the remote transmitter and press and hold the ON/HI button (see Fig. 11-1). The ignition sequen

Seite 4 - NOTES PAGE

12LIGHTING INSTRUCTIONS - 17 SERIES (cont.)SHUTTING DOWNMAIN BURNER ONLY (pilot will remain lit):For remote shut down, press and hold the LO/OFF butto

Seite 5 - APK-17 REPLACEMENT PARTS LIST

13TROUBLESHOOTINGPROBLEM CAUSE SOLUTION1. Pilot will not light a. Obstruction in pilot gas supply or pilot gas-supply line is kinkedb. Inadequate g

Seite 6 - INSTALLATION

14Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746 Quality Check Date:_________________Leak Test: ________________ Bu

Seite 7 - INSTALLATION (Cont.)

2L-A2-256Rev 6 - 1501210930TABLE OF CONTENTSGETTING STARTEDIMPORTANT INFORMATION ...

Seite 8

3L-A2-256Rev 6 - 1501210930CHECK TO BE SURE THAT THE PROPER FUEL GAS IS BEING USED WITH THIS PILOT KIT.The installation, including provisions for comb

Seite 9

4L-A2-256Rev 6 - 1501210930NOTES PAGEPlease use this page to record any information that you may want to have at hand.

Seite 10 - REMOTE LIGHTING (if equipped)

5L-A2-256Rev 6 - 15012109304APK-17 REPLACEMENT PARTS LIST26Note: Photos not to scale31Item Description Part No. Qty.1.Control valve SV-37

Seite 11 - MANUAL LIGHTING

6L-A2-256Rev 6 - 1501210930This safety pilot system must be installed by a qualifi ed professional service technician. Instructions must be followed ca

Seite 12 - PILOT BURNER CHECK/ADJUSTMENT

7L-A2-256Rev 6 - 1501210930FLAMEDIVERTERBRACKETBURNERPA N2 1/2REAR WALLBurner panFlame diverter bracket1-1/4"INSTALLATION (Cont.)INSTALL FLAME D

Seite 13 - TROUBLESHOOTING

8L-A2-256Rev 6 - 1501210930INSTALLATION (Cont.)CONNECT TO GAS SUPPLYTo connect the valve to the gas supply, the fl ex connector kit and component parts

Seite 14 - WARRANTY

9L-A2-256Rev 6 - 1501210930INSTALLATION (Cont.)CONNECT REMOTE RECEIVER (if equipped)Note: Discard the black wires that come with the remote receiver.